N4DBA06 8CH 0-5V 0-10V 4-20MA Voltage Current Signal Generator Detector RS485 to ADC DAC Converter Modbus RTU IO Module

N4DBA06 8CH 0-5V 0-10V 4-20MA Voltage Current Signal Generator Detector RS485 to ADC DAC Converter Modbus RTU IO Module

  • Model: N4DBA06
  • Availability: In stock
  • Weight: 0.04Kg
US$15.99
  • Description
  • Technical Documents
  • Guidance videos
  • Reviews
  • Shipping & Returns
Product Name: 8CH 0-5V 0-10V 4-20MA Voltage Current Signal Generator Detector RS485 to ADC DAC Converter Modbus RTU IO Module
 
 
Package inlcuded:
  1 x N4DBA06 12-25V 8-channel analog digital IO module
 
Description:
 
1Working voltage: DC 12 (DC 12-25V recommended power supply with small ripple)
 
2 Working current: 14-34MA (Related to the output current)
 
3 MODBUS RTU instruction support 03 06 function code
 
4 3 analog input channels, 1 switch input channel: Vi1 is 0-5V voltage input, Vi2 is 0-10V voltage input, Ii is 0-20MA current input; DiP DiN is switch input port (NPN/PNP Photoelectric isolation input)
 
5 3 analog output channels, 1 switch output channel: Vo1 is 0.05-5V voltage output (<20MA), Vo2 is 0.1-10V voltage output (<20MA), Io is 0.5-20MA current output; DoP DoN is Switch output port (maximum drive current 500MA, can directly drive relays and solenoid valves)
 
6 Voltage resolution is 0.01V, measurement accuracy is 1%; Current resolution is 0.01MA, measurement accuracy is 1%; if the error is greater than 1%, it can be calibrated
 
7 MODBUS commands can be made serial HyperTerminal (serial assistant) OR PLC Enter;
 
8 Under the MODBUS command mode, it can support up to 247 devices in parallel
 
9 Size: 60 * 72 * 18mm (Only PCB Board); 63 * 87 * 42mm (with Din Rail Box)
10 Weight: 33g (Only PCB Board); 85g (with Din Rail Box)
 
 
Instruction manual Please ask us after the purchase
 

DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 60 mm PCB boards
Net weight: 52g
Installation: DIN35 and C45 rail
 
 
Note:
1 Channel 1 (Vo1) output voltage range is 0.05V-5V, channel 2 (Vo2) output voltage range is 0.1V-10V, channel 3 (Io) output current range is 0.5-20MA
2 At the moment of power-on, the current and voltage output ports have 10-20MS high pulses
3 DiP DiN is a passive switch input port (see the figure below for wiring)
4 DoP DoN is a passive switch output port (see the figure below for wiring)



 
Application
4-20MA/0-20MA Sensor Multimeter
Current and voltage signal transmission measuring
Automated industry PLC
Smart Home,Home Automation ;
Identification system;
RS485 Remote monitoring;
Multimeter voltmeter

Interface introduction


 


 






 


 

 

Choose a ranking for this item. 1 star is the worst and 5 stars is the best.





NOTE: HTML tags are not allowed.
NOTE: Reviews require prior approval before they will be displayed

* Delivery Time.
We need 1-2 days to process your order before shipping.There are two shipping methoed. Fast Delivery: The delivery time for US, European countries the delivery will take 3-5 days.Slow Delivery: The delivery time for US, European countries the delivery will take 10-15 days.
* Tracking information.
After we ship package, customer receive automatic email with tracking details.
* Lost Package Policy.
If a package did not arrive in 4 weeks after the shipping date, then this package is treated as Lost. In this case a new package will be shipped to the customer provided we are able to give the same items as those purchased by the customer. If we are not able to provide the same items to substitute the lost ones we will either propose to the customer similar items or refund their cost as it will be mutually agree with the customer. If one or more items neither the same nor similar are available to be shipped, the customer can request to cancel the order entirely, thus the total cost of the order including shipping and handling cost will be fully refunded.

payment
Copyright © 2024 jinyiet.com All Rights Reserved.